Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Cien Saude Colet ; 25(3): 805-816, 2020 Mar.
Artigo em Português, Inglês | MEDLINE | ID: mdl-32159651

RESUMO

The study aimed to develop a Quantitative Health Inspection Instrument (IQIS) large-sized Brazilian food and nutrition services. The inspection technology based on the Potential Risk Assessment Model (MARP) and the Brazilian Health Legislation was used. Twelve dimensions, 41 modules, and 57 risk control (critical/non-critical) indicators were structured on a scale of 0-5, totalling 1,512 indices with closed-ended response coding. The IQIS was validated with the Kappa Coefficient, with excellent agreement for the attributes of clarity and relevance (k = 0.82 and k = 0.92) and good agreement for applicability (k = 0.78). The Kruskal-Wallis test showed no statistically significant difference between the assessments (p = 0.423), the Intraclass Correlation Coefficient was satisfactory (ICC = 0.53), and Cronbach's Alpha (α = 0.71) was acceptable. The final result made it possible to classify the service as having an unacceptable health risk. IQIS is considered to have validated content, be reliable and reproducible to assess the hygienic-sanitary conditions, being a technological innovation for food and nutrition services and sanitary, allowing a detailed and rigorous inspection.


O estudo visou desenvolver um Instrumento Quantitativo para Inspeção Sanitária (IQIS) em serviços de alimentação e nutrição de grande porte no Brasil. Utilizou-se a tecnologia de inspeção, no Modelo de Avaliação do Risco Potencial (MARP) e legislação sanitária brasileira. Estruturaram-se 12 dimensões, 41 módulos, 57 indicadores de controle de riscos (críticos/não críticos), numa escala de 0-5, totalizando 1.512 índices com codificação de respostas fechadas. O IQIS foi validado com o Coeficiente de Kappa, com excelente concordância para atributos de clareza e relevância (k = 0,82 e k = 0,92) e boa concordância para o atributo aplicabilidade (k = 0,78). O teste de Kruskal-Wallis mostrou inexistir diferença significativa entre as avaliações (p = 0,423), o Coeficiente de Correlação Intraclasse foi satisfatório (CCI = 0,53), o Alpha de Cronbach (α = 0,71) aceitável. O resultado final possibilitou classificar o serviço como tendo risco sanitário inaceitável. Considera-se o IQIS com conteúdo validado, tendo confiabilidade e reprodutibilidade para avaliação higiênico-sanitária, sendo uma inovação tecnológica para serviços de alimentação e nutrição e vigilância sanitária, possibilitando inspeção detalhada e rigorosa.


Assuntos
Inocuidade dos Alimentos/métodos , Serviços de Alimentação/normas , Brasil , Estudos de Avaliação como Assunto , Humanos , Medição de Risco
2.
Ciênc. Saúde Colet. (Impr.) ; 25(3): 805-816, mar. 2020. tab, graf
Artigo em Português | LILACS | ID: biblio-1089485

RESUMO

Resumo O estudo visou desenvolver um Instrumento Quantitativo para Inspeção Sanitária (IQIS) em serviços de alimentação e nutrição de grande porte no Brasil. Utilizou-se a tecnologia de inspeção, no Modelo de Avaliação do Risco Potencial (MARP) e legislação sanitária brasileira. Estruturaram-se 12 dimensões, 41 módulos, 57 indicadores de controle de riscos (críticos/não críticos), numa escala de 0-5, totalizando 1.512 índices com codificação de respostas fechadas. O IQIS foi validado com o Coeficiente de Kappa, com excelente concordância para atributos de clareza e relevância (k = 0,82 e k = 0,92) e boa concordância para o atributo aplicabilidade (k = 0,78). O teste de Kruskal-Wallis mostrou inexistir diferença significativa entre as avaliações (p = 0,423), o Coeficiente de Correlação Intraclasse foi satisfatório (CCI = 0,53), o Alpha de Cronbach (α = 0,71) aceitável. O resultado final possibilitou classificar o serviço como tendo risco sanitário inaceitável. Considera-se o IQIS com conteúdo validado, tendo confiabilidade e reprodutibilidade para avaliação higiênico-sanitária, sendo uma inovação tecnológica para serviços de alimentação e nutrição e vigilância sanitária, possibilitando inspeção detalhada e rigorosa.


Abstract The study aimed to develop a Quantitative Health Inspection Instrument (IQIS) large-sized Brazilian food and nutrition services. The inspection technology based on the Potential Risk Assessment Model (MARP) and the Brazilian Health Legislation was used. Twelve dimensions, 41 modules, and 57 risk control (critical/non-critical) indicators were structured on a scale of 0-5, totalling 1,512 indices with closed-ended response coding. The IQIS was validated with the Kappa Coefficient, with excellent agreement for the attributes of clarity and relevance (k = 0.82 and k = 0.92) and good agreement for applicability (k = 0.78). The Kruskal-Wallis test showed no statistically significant difference between the assessments (p = 0.423), the Intraclass Correlation Coefficient was satisfactory (ICC = 0.53), and Cronbach's Alpha (α = 0.71) was acceptable. The final result made it possible to classify the service as having an unacceptable health risk. IQIS is considered to have validated content, be reliable and reproducible to assess the hygienic-sanitary conditions, being a technological innovation for food and nutrition services and sanitary, allowing a detailed and rigorous inspection.


Assuntos
Humanos , Inocuidade dos Alimentos/métodos , Serviços de Alimentação/normas , Brasil , Medição de Risco , Estudos de Avaliação como Assunto
3.
Radiat Prot Dosimetry ; 154(2): 229-36, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22908350

RESUMO

This study aims to contribute to the construction of a scenario regarding patient radiation exposure in Brazilian interventional radiology, aiming to provide data for the future drafting of specific legislation on interventional radiology because there is currently a lack of safety regulations for haemodynamics services in this country. Fourteen haemodynamics services in the states of Santa Catarina and Bahia were evaluated. The radiological devices were characterised through measurements of air kerma-area product, entrance surface air kerma (Ke), exposure time, spatial resolution (SR), low-contrast resolution and half-value layer. During the evaluation of instrument parameters, several non-conformities were found according to current Brazilian regulations, with SR presenting the most critical situation. The results of the present study indicate the need for the optimisation of clinical practices in complex radiological procedures, although the overall results for the dose scenario in the present study revealed values similar to those reported in international publications.


Assuntos
Exposição Ocupacional/análise , Lesões por Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Radiologia Intervencionista/métodos , Brasil , Humanos , Doses de Radiação , Monitoramento de Radiação , Proteção Radiológica
4.
Radiol. bras ; 45(4): 210-214, jul.-ago. 2012. graf, tab
Artigo em Português | LILACS | ID: lil-647861

RESUMO

OBJETIVO: Avaliar as exposições pediátricas de radiologia intervencionista em dois hospitais do Estado da Bahia, visando contribuir para a construção de um cenário estadual e nacional, possibilitando o conhecimento das exposições e da necessidade de sua otimização, visto que as peculiaridades que envolvem a radiologia e a pediatria se potencializam quando se trata de procedimentos de radiologia intervencionista, em razão das doses elevadas de radiação. MATERIAIS E MÉTODOS: Foram avaliados 32 procedimentos em quatro salas nos dois principais hospitais que realizam procedimentos de radiologia intervencionista pediátrica na Bahia. Foram avaliados os valores de kerma no ar incidente e o produto kerma-área no ar de 27 procedimentos cardiológicos e 5 procedimentos cerebrais. RESULTADOS: Os valores máximos de produto kerma-área e kerma obtidos para procedimentos cardiológicos foram, respectivamente, 129,9 Gy.cm² e 947,0 mGy, e para procedimentos cerebrais, 83,3 Gy.cm² e 961,0 mGy. CONCLUSÃO: Os resultados deste estudo mostraram valores de exposições superiores em até 14 vezes os obtidos em estudos realizados em outros países, chegando próximos de resultados obtidos para procedimentos em adultos. Isto revela quão elevadas podem ser as exposições pediátricas, indicando a necessidade de constante otimização dos procedimentos e avaliação das exposições.


OBJECTIVE: To evaluate pediatric radiation exposure in procedures of interventional radiology in two hospitals in the Bahia state, aiming at contributing to delineate the scenario at the state and national levels. The knowledge of exposure levels will allow an evaluation of the necessity of doses optimization, considering that peculiarities of radiology and pediatrics become even more significant in interventional radiology procedures which involve exposure to higher radiation doses. MATERIALS AND METHODS: A total of 32 procedures were evaluated in four rooms of the two main hospitals performing pediatric interventional radiology procedures in the Bahia state. Air kerma rate and kerma-area product were evaluated in 27 interventional cardiac and 5 interventional brain procedures. RESULTS: Maximum values for air kerma rate and kerma-area product and air kerma obtained in cardiac procedures were, respectively, 129.9 Gy.cm² and 947.0 mGy; and, for brain procedures were 83.3 Gy.cm² and 961.0 mGy. CONCLUSION: The present study results showed exposure values up to 14 times higher than those found in other foreign studies, and approximating those found for procedures in adults. Such results demonstrate excessive exposure to radiation, indicating the need for constant procedures optimization and evaluation of exposure rates.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Lactente , Pré-Escolar , Criança , Adolescente , Cérebro , Coração , Imagem por Ressonância Magnética Intervencionista , Kerma , Radiologia Intervencionista , Interpretação Estatística de Dados
5.
Salvador; EDUFBA; 2 ed; 2012. 165 p. graf, tab.
Monografia em Português | Sec. Munic. Saúde SP, AHM-Acervo, TATUAPE-Acervo, COVISA-Acervo, EMS-Acervo, HSPM-Acervo | ID: sms-5835
6.
Salvador; EDUFBA; 2 ed; 2012. 165 p. graf, tab.
Monografia em Português | LILACS, EMS-Acervo | ID: lil-669986
7.
Cien Saude Colet ; 15 Suppl 3: 3477-86, 2010 Nov.
Artigo em Português | MEDLINE | ID: mdl-21120335

RESUMO

The X-ray diagnostic is one of the main diagnosis tools in medicine and its role, in public health, depends on the quality of the exams, the regulatory responsibility fits, mainly, in the National System of Sanitary Surveillance. With this perspective, it was developed a mathematical evaluation model of potential risks in radiodiagnostic and, through its use in the Brazilian health services of Bahia state, with the analysis of the situation found and its determinants. With that model, 94 procedures were evaluated in 38 Bahia state radiodiagnostic services. The study showed that 5.3% of the services had all of the procedures in level of acceptable potential risk. 23.7% showed, at least, one procedure with level of tolerable potential risk and 71% showed, at least, one procedure with a level of unacceptable potential risk. The analyses shows that the main determinants of the encountered situation are the deficient inspection by the sanitary surveillance system of the health services and of the industrial sector, the absence of basics of radiological protection in the curriculum of medicine courses and the fragility of practices control, by the respective professional council.


Assuntos
Vigilância da População , Radiografia/efeitos adversos , Brasil , Medição de Risco , Gestão de Riscos
8.
Ciênc. Saúde Colet. (Impr.) ; 15(supl.3): 3477-3486, nov. 2010. ilus, graf, tab
Artigo em Português | LILACS | ID: lil-566019

RESUMO

O radiodiagnóstico é uma das principais ferramentas de diagnose na medicina e seu papel, na saúde pública, depende da qualidade dos exames, cuja responsabilidade regulatória cabe principalmente ao Sistema Nacional de Vigilância Sanitária. Nessa perspectiva, foi desenvolvido um modelo matemático de avaliação de riscos potencial (MARP) em radiodiagnóstico e, através do seu uso em serviços de saúde da Bahia, analisada a situação encontrada e seus condicionantes. O MARP baseia-se no conceito de risco potencial e relaciona os indicadores de controle de riscos com os riscos potenciais e os responsáveis pelos controles. Usando esse modelo, avaliaram-se 94 procedimentos de 38 serviços de radiodiagnóstico. O estudo mostrou que 5,3 por cento dos serviços estavam com todos os procedimentos em nível de risco potencial aceitável. 23,7 por cento tinham pelo menos um procedimento com nível de risco potencial tolerável, e 71 por cento tinham pelo menos um procedimento com nível de risco potencial inaceitável. As análises mostraram que os principais condicionantes da situação encontrada dizem respeito à deficiência do sistema de vigilância sanitária na fiscalização dos serviços e da indústria, à ausência dos fundamentos de proteção radiológica nas diretrizes curriculares dos cursos de medicina e à fragilidade do controle das práticas pelos respectivos conselhos profissionais.


The X-ray diagnostic is one of the main diagnosis tools in medicine and its role, in public health, depends on the quality of the exams, the regulatory responsibility fits, mainly, in the National System of Sanitary Surveillance. With this perspective, it was developed a mathematical evaluation model of potential risks in radiodiagnostic and, through its use in the Brazilian health services of Bahia state, with the analysis of the situation found and its determinants. With that model, 94 procedures were evaluated in 38 Bahia state radiodiagnostic services. The study showed that 5.3 percent of the services had all of the procedures in level of acceptable potential risk. 23.7 percent showed, at least, one procedure with level of tolerable potential risk and 71 percent showed, at least, one procedure with a level of unacceptable potential risk. The analyses shows that the main determinants of the encountered situation are the deficient inspection by the sanitary surveillance system of the health services and of the industrial sector, the absence of basics of radiological protection in the curriculum of medicine courses and the fragility of practices control, by the respective professional council.


Assuntos
Vigilância da População , Radiografia/efeitos adversos , Brasil , Medição de Risco , Gestão de Riscos
9.
Hist. ciênc. saúde-Manguinhos ; 15(4): 1039-1047, out.-dez. 2008.
Artigo em Português | LILACS | ID: lil-506987

RESUMO

Apresenta o histórico da descoberta das radiações ionizantes, seus efeitos biológicos e a conseqüente necessidade de controle dos respectivos riscos à saúde. Descreve a evolução histórica do controle de risco em radiodiagnóstico no Brasil, demonstrando que este pode não estar associado apenas à dose recebida, mas também a erros de diagnóstico e a custos para o sistema de saúde. Salienta que a legislação sanitária tem um amplo leque de co-responsabilidade social para envolver todos os atores visando à proteção da saúde.


Assuntos
Gestão de Riscos/história , História da Medicina , Medicina Preventiva/história , Radiação Ionizante , Radiologia/história , Saúde Pública/história , Brasil
10.
Hist. ciênc. saúde-Manguinhos ; 15(4): 1039-1047, out.-dez. 2008.
Artigo em Português | HISA - História da Saúde | ID: his-16377

RESUMO

Apresenta o histórico da descoberta das radiações ionizantes, seus efeitos biológicos e a conseqüente necessidade de controle dos respectivos riscos à saúde. Descreve a evolução histórica do controle de risco em radiodiagnóstico no Brasil, demonstrando que este pode não estar associado apenas à dose recebida, mas também a erros de diagnóstico e a custos para o sistema de saúde. Salienta que a legislação sanitária tem um amplo leque de co-responsabilidade social para envolver todos os atores visando à proteção da saúde. (AU)


Assuntos
Saúde Pública/história , Medicina Preventiva/história , História da Medicina , Gestão de Riscos/história , Radiação Ionizante , Radiologia/história , Brasil
11.
Hist Cienc Saude Manguinhos ; 15(4): 1039-47, 2008.
Artigo em Português | MEDLINE | ID: mdl-19824324

RESUMO

This paper presents the history of the discovery of ionizing radiation, as well as its biological effects and the resulting need to control subsequent health risks. It describes the historic evolution of risk control in radiodiagnosis in Brazil, demonstrating that it may be associated not only to the dose received, but also to errors in diagnosis and to costs to the health system. It is stressed that sanitary regulations have a broad remit of social co-responsibility to involve all the players with a view to safeguarding health.


Assuntos
Física Médica/história , Lesões por Radiação/história , Radiografia/história , Brasil , Física Médica/legislação & jurisprudência , História do Século XIX , História do Século XX , Humanos , Lesões por Radiação/prevenção & controle , Radiação Ionizante , Radiografia/efeitos adversos , Risco
12.
Salvador; s.n; nov. 2007. 147 p. ilus.
Tese em Português | LILACS | ID: lil-519476

RESUMO

Este estudo analisa o controle de riscos em radiodiagnóstico e seus condicionantes, considerando o marco regulatório vigente e identificando os diversos atores implicados nesta prática. O radiodiagnóstico é uma das principais ferramentas de diagnose da medicina moderna, sendo de fundamental importância para a detecção e acompanhamento de diversos agravos à saúde. Seu papel na saúde pública dependerá do controle e da qualidade dos exames e processos envolvidos, podendo representar um indispensável apoio diagnóstico ou um grave problema devido a informações diagnósticas incorretas ou incompletas, as exposições de pacientes, de trabalhadores e de indivíduos do público. Considerando que a vigilância sanitária, entendida como um campo de conhecimento científico e de práticas organizadas, visando à proteção da saúde, ainda está em processo de consolidação, além da descrição situacional, foram realizadas contribuições teóricas e metodológicas relacionadas ao conceito, controle e operacionalização da avaliação de riscos sanitários. Neste sentido, este trabalho propõe a utilização do conceito de risco potencial, com base no qual foi desenvolvido um modelo matemático para avaliação de risco potencial, utilizando os indicadores de controle de riscos estabelecidos no marco regulatório do radiodiagnóstico. Foram avaliados 94 procedimentos (7 de fluoroscopia, 14 de mamografia, 60 de radiografia convencional e 13 de tomografia) de 38 serviços de radiodiagnóstico no Estado da Bahia, analisando-se os condicionantes da situação encontrada...


Assuntos
Vigilância Sanitária , Proteção Radiológica , Radiografia , Radiologia , Gestão de Riscos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...